Micropiles execution for the foundations of the church’s extension. The 19 micropiles have a diameter of 220 mm and a length varying between 15 and 25 meters. They will distribute the tension effects of the large overhanging concrete shells into the ground. A direct tension test was conducted on a test micropile to confirm the design values.